Services List
Download Catalog
π¨οΈ Director's Thought
"In the digital age, your datacenter is the heartbeat of your business. At CBS, we don't just build server roomsβwe architect the foundation for your digital future."
β Amarjeet, Director, CBS
π Case Study Spotlight
A leading healthcare provider partnered with CBS to build a Tier-3 datacenter, achieving 99.99% uptime and reducing operational costs by 40% through optimized cooling and power management.
An e-commerce giant scaled from 50 to 500 racks with our modular datacenter solution, supporting 10x traffic growth during peak seasons without downtime.
π― Is It For You?
If you're looking to:- β Build a new datacenter from ground up
- β Upgrade existing infrastructure
- β Improve energy efficiency
- β Ensure business continuity
- β Scale operations seamlessly
Then yes, CBS Datacenter Solutions are for you.
Engineering the Digital Fortress
End-to-end datacenter solutions that combine architectural excellence, operational resilience, and future-ready scalability.
In an era where data has surpassed oil as the world's most valuable resource, your datacenter is no longer just a facilityβit is the strategic nerve center of your enterprise. At Computerized Business Solutions (CBS), we understand that every second of downtime translates to lost revenue, eroded customer trust, and competitive disadvantage.
The Business Case for Modern Datacenters
Data Explosion
60% of enterprises face storage capacity crises annually. Our scalable architectures grow with your data footprint.
Downtime Costs
Average cost of unplanned outage: $5,600/minute. Tier-III/IV designs deliver 99.982%-99.995% availability.
Energy Inefficiency
Datacenters consume 1-2% of global electricity. PUE optimization reduces energy costs by 30-50%.
Security Threats
Physical & cyber attacks increased 400% since 2020. Layered security with biometric, surveillance, and zero-trust models.
Our Solution Architecture
We approach every project through a holistic lens, ensuring all critical domains work in harmony.
β βββββββββββββββ βββββββββββββββ βββββββββββββββ β
β β PHYSICAL β β POWER & β β COOLING & β β
β β INFRASTRUCT.β β ELECTRICAL β β CLIMATE β β
β βββββββββββββββ βββββββββββββββ βββββββββββββββ β
β βββββββββββββββ βββββββββββββββ βββββββββββββββ β
β β NETWORK & β β SECURITY & β β MANAGEMENT β β
β β CONNECTIVITYβ β ACCESS β β & MONITORINGβ β
β βββββββββββββββ βββββββββββββββ βββββββββββββββ β
β βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ β
β β ORCHESTRATION LAYER: DCIM + AUTOMATION β β
β βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ β
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
π Power & Electrical Engineering
CBS Approach: N+1, 2N, and 2(N+1) redundancy architectures β’ Intelligent PDUs with outlet-level monitoring β’ Lithium-ion UPS systems with 50% smaller footprint β’ Automatic transfer switches (ATS) β’ On-site generator integration
Outcome: Zero single points of failure; predictable power availability regardless of grid conditions.
βοΈ Precision Cooling & Thermal Management
CBS Approach: Computational Fluid Dynamics (CFD) modeling β’ Hot aisle/cold aisle containment β’ Liquid cooling readiness for high-density compute β’ Free cooling economizers β’ Real-time temperature mapping
Outcome: PUE below 1.4; 20-40% reduction in cooling OPEX.
Tier Classifications We Support
| Tier | Uptime | Annual Downtime | Best Suited For |
|---|---|---|---|
| Tier I | 99.671% | 28.8 hours | Small business, non-critical workloads |
| Tier II | 99.741% | 22.0 hours | Mid-sized, some redundancy needs |
| Tier III | 99.982% | 1.6 hours | Enterprise, concurrent maintenance critical |
| Tier IV | 99.995% | 26.3 minutes | Financial, healthcare, mission-critical |
CBS also designs hybrid tier modelsβTier-III compute zones with Tier-IV power for critical workloadsβoptimizing cost without compromising resilience.
Our Proven Methodology
Discovery & Strategic Alignment
Business impact analysis, current state assessment, 3-5 year growth modeling.
Site Selection & Feasibility
Power availability, fiber connectivity, seismic risk, climate suitability.
Design & Engineering
Architectural blueprints, 3D BIM modeling, vendor selection.
Construction & Integration
Project management, factory testing, staged commissioning.
Transition & Empowerment
Operational Runbook, team training, 90-day hypercare.
Ongoing Partnership
24/7 remote monitoring, preventive maintenance, quarterly reviews.
Case Studies: Proven Results
π₯ National Healthcare Network
Challenge: 12-hospital network with aging server rooms; compliance concerns; frequent heat-related outages.
CBS Solution: Regional Tier-III datacenter, N+1 redundant cooling, DCIM implementation, HIPAA-compliant security.
Results: 99.99% uptime achieved β’ 40% reduction in cooling OPEX β’ Zero compliance findings β’ 3-year ROI of 215%
π E-Commerce Unicorn
Challenge: 400% YoY growth; existing colocation space exhausted; peak traffic causing thermal shutdowns.
CBS Solution: Modular datacenter with phased deployment, high-density racks (15kW/rack), liquid cooling readiness, 100GbE backbone.
Results: Scaled from 50 to 500 racks in 18 months β’ Supported 10x traffic growth with zero downtime β’ PUE reduced from 1.9 to 1.35
ποΈ Government Agency
Challenge: Security-sensitive operations; required air-gapped infrastructure; strict procurement compliance.
CBS Solution: Tier-IV certified design, multi-layered physical security, TEMPEST-compliant shielding.
Results: Operational within 14 months β’ Passed all security certifications β’ 15-year infrastructure lifecycle plan established
Engagement Models
End-to-End Build
Full responsibility from design to handover. Best for organizations without internal infrastructure teams.
Design-Assist
CBS designs; you (or your GC) build. Ideal for clients with construction partners who want expert design.
Advisory & Audit
Expert assessment and recommendations. For organizations validating existing plans or troubleshooting.
Support & Optimization
Operational monitoring and maintenance. For existing datacenter owners seeking performance improvement.
Green Datacenter Imperative
Datacenters account for approximately 1% of global electricity consumptionβprojected to double by 2030. CBS is committed to sustainable design.
Reduce from 1.8 to <1.4
Eliminate chiller usage 3,000+ hours/year
Support 2-3x compute density
Offset 20-40% of grid consumption
96-97% efficiency
Zero-landfill disposition
Case Example: For a financial services client, CBS implemented a free-cooling solution that reduced annual cooling energy consumption by 2.4 million kWhβequivalent to removing 380 cars from the road annually.
Technical Partners & Innovation Ecosystem
Schneider Electric, Vertiv, Eaton, APC
Stulz, Liebert, Trane, Carrier
Rittal, Chatsworth, APC
Cisco, Juniper, Arista
Sunbird, Nlyte, EcoStruxure
AWS, Microsoft Azure, Google Cloud
CBS vs The Alternatives
| Factor | DIY / In-House | CBS | Generic Vendor |
|---|---|---|---|
| Time to Deploy | 18-24 months | 8-14 months β | 12-18 months |
| Cost Predictability | 40% overrun typical | Fixed price, guaranteed β | Hidden costs common |
| Uptime Guarantee | None | 99.99% SLA β | 99.9% (8.7 hrs downtime/yr) |
| Post-Build Support | Hire & train team | 24/7 included β | Extra fees apply |
| Vendor Management | 15+ contracts to manage | Single point of contact β | 5-8 vendors |
Frequently Asked Questions
Q: How long does a typical datacenter project take?
A: Timeline depends on scale and tier. A 100-rack Tier-III facility typically takes 8-12 months from kickoff to go-live. We provide detailed Gantt charts during the proposal phase and guarantee our delivery dates with contractual penalties for delays.
Q: Can you upgrade our existing facility or do you only do greenfield builds?
A: About 40% of our projects are retrofits or expansions. We excel at "hot" upgrades (maintaining operations during construction) and can typically increase capacity by 2-3x in existing footprints through density optimization.
Q: What ongoing costs should we budget post-construction?
A: We design for OPEX efficiency. Typical CBS datacenters run at 30-40% lower annual operating costs than industry average due to PUE optimization and smart monitoring. We provide 5-year TCO projections during design.
Q: Do you handle all the compliance and certifications?
A: Yes. We manage Tier certification (Uptime Institute), LEED, ISO 27001, and industry-specific compliance (HIPAA, PCI-DSS, SOC2) as part of our end-to-end service. Our team includes certified auditors.
Q: What happens after the datacenter is built?
A: We don't disappear. 90% of our clients opt for our managed services. We offer 24/7 remote monitoring, preventive maintenance, and on-call engineering. Our average response time is 15 minutes; resolution time averages 2 hours for critical issues.
Certifications & Standards
Ready to Build Your Digital Fortress?
Get a free infrastructure assessment and roadmap. No commitment required.
β Response within 4 hours | β Free site assessment | β Detailed proposal in 48 hours
π Service Coverage
Headquartered in Bangalore, India with active projects across Delhi NCR, Mumbai, Chennai, Hyderabad, Pune, and Kolkata. We serve clients nationwide with local engineering teams and partners in all major metros.